Dual-Path Signalling Explained: How to Ensure Your Alarm Always Reaches the Police

Nov 17, 2026 | CCTV

Imagine this: a sophisticated intruder targets your business. They’ve done their homework. Before even attempting to force a door, they find the external telephone or broadband line and snip it. In their mind, they’ve just silenced your security system.

With a standard, single-path alarm, they’d be right. The "brain" of your alarm would try to call for help, find the "road" blocked, and simply give up.

But with dual-path signalling, that intruder is in for a very nasty surprise. While the primary line might be dead, the secondary path: a secure, encrypted radio signal: has already alerted the Monitoring Centre. Within seconds, the police are on their way.

At JKE Fire & Security, we believe security should be dependable, not "hopeful." In this guide, we’ll explain exactly why dual-path signalling is the gold standard for intruder alarms and why, if you value police response, it’s no longer just an "option": it’s a necessity.

What is Dual-Path Signalling?

In the world of security, "signalling" is simply the way your alarm panel talks to the outside world. When a sensor is triggered, the panel needs to send a digital "help" message to an Alarm Receiving Centre (ARC).

Single-Path Signalling uses one method: usually your building’s broadband (IP) or a phone line. If that one connection fails, the alarm stays silent.

Dual-Path Signalling uses two completely independent "roads" to send that message. Typically, this is a combination of:

  1. Path A (Wired): Your local area network or broadband (IP). It’s fast and handles a lot of data.
  2. Path B (Wireless): A dedicated roaming SIM card that uses 4G or 5G mobile networks.

Because these two paths don't rely on the same infrastructure, it is incredibly difficult for an intruder: or a random technical glitch: to stop the signal from getting through.

A professionally installed Texecom Premier intruder alarm panel, the

Why Two Paths are Better Than One

The primary benefit is redundancy. If a construction crew down the street accidentally digs up a fiber optic cable, your business's internet goes down. If you have single-path signalling, your security goes down with it.

With a dual-path system (like the ones we install using CSL DualCom technology), the system is constantly "polling." This means the alarm panel and the ARC are effectively checking each other's pulse every few minutes.

  • If the Broadband Fails: The system instantly switches all traffic to the 4G/5G radio path. You get an alert that your internet is down, but your security remains at 100% strength.
  • If the Radio Signal is Jammed: The system continues to use the wired IP path.
  • If Both Fail: The ARC is alerted immediately that communication has been lost. Under UK police rules, a total loss of dual-path communication while the system is armed is often treated as a "confirmed alarm," which can trigger a police dispatch even if no sensors have been tripped yet.

The "Redcare" Crisis: Why You Need to Check Your System Now

For decades, many UK businesses relied on a service called BT Redcare. It was the industry standard for high-security signalling. However, BT has announced that they are closing the Redcare service permanently in early 2025.

If your current alarm system relies on Redcare, it will stop working. This isn't just a technical annoyance; it could invalidate your insurance and cause your police response (your URN) to be withdrawn.

At JKE, we are currently helping our clients migrate from legacy systems to modern, dual-path alternatives like CSL GradeShift Pro. These new systems are faster, more secure, and don't rely on old-fashioned copper phone lines that are being phased out across the UK anyway.

A security operator in a high-tech control room monitoring live feeds and alarm signals to ensure a rapid response.

Understanding the "Grades" (DP1 to DP4)

When you look at dual-path signalling, you’ll see terms like "DP2" or "DP3." These refer to how quickly the system reports a failure.

  • DP2: The system checks in regularly. If both paths fail, the ARC knows within about 30 minutes. This is standard for most small businesses and homes.
  • DP3: A higher level of security. Failure is detected within minutes. Often required by insurers for high-value retail or warehouses.
  • DP4: The "Gold Standard." If communication is lost, the ARC knows within seconds. This is typically used for high-risk sites like banks, pharmacies, or government buildings.

Choosing the right grade isn't about guesswork; it’s about matching the risk level of your property and meeting the specific requirements of your insurance policy. If you're unsure what you need, our team can provide honest advice based on your specific site.

How It Guarantees Police Response

In the UK, the police don't just turn up for any ringing bell. To get a guaranteed police response, your system must have a Unique Reference Number (URN) and be monitored by an accredited ARC.

The police have a "confirmed alarm" policy. They generally only attend if:

  1. Two separate sensors are triggered (e.g., a door contact AND a motion sensor).
  2. OR both paths of a dual-path signalling system fail simultaneously while the system is set.

By having dual-path signalling, you are essentially telling the police: "If you hear from us, it's a real emergency." This reduces false alarms and ensures that when you actually need the authorities, they take the call seriously.

A JKE-branded alarm sounder and CCTV cameras on a commercial building, providing visible deterrence and professional monitoring.

More Than Just Security: The Benefits of Maintenance & Monitoring

Modern dual-path systems offer more than just a link to the police. Because they are "always on" and connected to the cloud, they provide several practical benefits for business owners:

  • Remote Management: You can often see the status of your system via a smartphone app.
  • Reduced False Alarms: Because the system is more intelligent, it can distinguish between a technical fault (like a power cut) and a genuine break-in.
  • Insurance Compliance: Many commercial insurers now mandate dual-path signalling as a condition of their cover. Without it, you might find a claim rejected after a burglary.
  • Peace of Mind: Knowing that your system has a "backup for its backup" allows you to leave the office or your home without worrying about "what if the internet goes down?"

A hand holding a smartphone with the JKE Fire & Security app, showing 24/7 support and remote system access.

Is Your System Up to the Task?

Security technology moves fast. If your alarm system was installed more than five years ago, there is a high chance it is relying on single-path signalling or a legacy service like BT Redcare that is nearing the end of its life.

Switching to dual-path signalling is a straightforward process that involves installing a small "communicator" inside your existing alarm panel. It’s a small investment that offers a massive increase in reliability.

At JKE Fire & Security, we don't just "box shift." We take a solution-led approach, ensuring your system is designed properly, documented clearly, and supported long-term. We specialise in making compliance easy so you can focus on running your business.

Not sure what signalling your alarm is using? Get in touch with our team today. We’ll give you a plain-English assessment of your current setup and help you ensure that your "call for help" always reaches the right people.